<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-14T05:29:28Z</responseDate><request identifier="10.22000/a5juqpkyz2xxzv7f" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.22000/a5juqpkyz2xxzv7f</identifier><datestamp>2026-10-09T11:51:13Z</datestamp><setSpec>radar4chem</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.22000/a5juqpkyz2xxzv7f</dc:identifier>
   <dc:creator>Lehnertz, Marcus S.</dc:creator>
   <dc:creator>Dufour, Sylvie</dc:creator>
   <dc:creator>Becker, Tabea</dc:creator>
   <dc:creator>Thiele, Isabel</dc:creator>
   <dc:creator>Waldburger, Saskia</dc:creator>
   <dc:creator>Raquez, Jean-Marie</dc:creator>
   <dc:creator>Herres-Pawlis, Sonja</dc:creator>
   <dc:creator>Riedel, Sebastian L.</dc:creator>
   <dc:creator>Palkovits, Regina</dc:creator>
   <dc:title>Experimental Data to the publication „Impact of molecular weight, additives and copolymers on the chemical recycling of (bio)plastics using solid Ruthenium-based catalysts”</dc:title>
   <dc:publisher>RWTH Aachen University</dc:publisher>
   <dc:date>2026</dc:date>
   <dc:subject>Chemistry</dc:subject>
   <dc:subject>Materials Science</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>SEC and HPLC experimental data</dc:subject>
   <dc:subject>Dataset</dc:subject>
   <dc:source>GPCmax VE-2001 from Viscotek: two Malvern Viscotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 and 5000Å, a refractive index detector (VE-3580), and a viscometer (Viscotek 270 Dual Detector)</dc:source>
   <dc:source>Shimadzu LCMS-2020, equipped with a RI detector. The flow was set to 2.0 mL min-1, and the eluent was a mixture of water and TFA with a concentration of 154 µL L-1. The organic acid resin column with dimensions of 300 x 8 mm was delivered by CS chromatography. The oven temperature was set to 40 °C.</dc:source>
   <dc:source>Instrument</dc:source>
   <dc:source>Instrument</dc:source>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/legalcode</dc:rights>
   <dc:description>Further SEC data and HPLC data for the chemical recycling of PLA and PHA with Ru/CeO2 catalysts were deposited.</dc:description>
   <dc:subject>Size Exclusion chromatography</dc:subject>
   <dc:subject>polymer recycling</dc:subject>
   <dc:subject>depolymerization</dc:subject>
   <dc:subject>High-Performance Liquid Chromatography</dc:subject>
   <dc:subject>polylactide</dc:subject>
   <dc:subject>polyhydroxyalkanoate</dc:subject>
   <dc:language>eng</dc:language>
   <dc:relation>https://doi.org/10.13039/501100001659</dc:relation>
   <dc:relation>https://doi.org/10.13039/501100002347</dc:relation>
   <dc:format>application/x-tar</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>