<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-13T23:02:47Z</responseDate><request identifier="10.22000/ab0bmuwhdgfs0tqq" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.22000/ab0bmuwhdgfs0tqq</identifier><datestamp>2026-10-09T11:51:09Z</datestamp><setSpec>radar4chem</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.22000/ab0bmuwhdgfs0tqq</dc:identifier>
   <dc:creator>Seitz, Tobias</dc:creator>
   <dc:creator>Karabulut, Aylin </dc:creator>
   <dc:creator>Hoffmann, Alexander</dc:creator>
   <dc:creator>Herres-Pawlis, Sonja</dc:creator>
   <dc:title>Experimental Data to the publication "The Golden Goal of Entatic State Model Design: Lowering the Internal Reorganization Energy Leads to Exponential Increase in Electron Transfer Rate"</dc:title>
   <dc:publisher>RWTH Aachen University</dc:publisher>
   <dc:date>2025</dc:date>
   <dc:subject>Chemistry</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Dataset</dc:subject>
   <dc:source>The measurements were performed with a METROHM AUTOLAB PGSTAT 101 potentiostat using a three-electrode arrangement with a Pt disc working electrode (1 mm diameter), a Pt wire as counter electrode and an Ag/AgCl (in saturated ethanolic LiCl) reference electrode. The measurements were performed in MeCN and 100 mmol/L NBu4PF6 with a sample concentration of 1 mmol/L at room temperature. Ferrocene was added as an internal standard after the measurements of the sample and all potentials are referenced relative to the Fc/Fc+ potential. Cyclic voltammograms were measured with 200 mV s –1, 100 mV s –1, 50 mV s –1 and 20 mV s –1. </dc:source>
   <dc:source>The stopped-flow measurements were performed with a HI-TECH Scientific SF-61SX2 device with a diode array detector. The optical light path for transmission of the quartz glass cuvette was 10 mm. The mixing time is given by HI-TECH to amount to 2 ms. UV/Vis spectra in a wavelength range of 300 nm to 800 nm were detected with temporal resolutions of 0.75 to 7.5 s. </dc:source>
   <dc:source>Instrument</dc:source>
   <dc:source>Instrument</dc:source>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/legalcode</dc:rights>
   <dc:description>Cyclic voltammetric data, UV/Vis spectroscopic data and DFT optimized structures of the complexes are deposited.</dc:description>
   <dc:subject>electron transfer</dc:subject>
   <dc:subject>guanidine complexes</dc:subject>
   <dc:subject>electron self-exchange</dc:subject>
   <dc:subject>copper complexes</dc:subject>
   <dc:language>eng</dc:language>
   <dc:relation>501100001659</dc:relation>
   <dc:format>application/x-tar</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>