<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-14T05:15:10Z</responseDate><request identifier="10.22000/drn56dwfku72hn16" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.22000/drn56dwfku72hn16</identifier><datestamp>2026-10-09T11:51:14Z</datestamp><setSpec>radar4chem</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.22000/drn56dwfku72hn16</dc:identifier>
   <dc:creator>Schmidt, Regina</dc:creator>
   <dc:creator>Weinelt, Leander</dc:creator>
   <dc:creator>Laurini, Larissa</dc:creator>
   <dc:creator>Becker, Nils Jannis</dc:creator>
   <dc:creator>Hoffmann, Alexander</dc:creator>
   <dc:creator>Herres-Pawlis, Sonja</dc:creator>
   <dc:title>Experimental Data to the publication „Unraveling the Electron Transfer Mechanism in the Reduction of Bis(µ-oxido) Dicopper Complexes”</dc:title>
   <dc:publisher>RWTH Aachen University</dc:publisher>
   <dc:date>2026</dc:date>
   <dc:subject>Chemistry</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Data of UV/Vis spectroscopic titration measurements, of stopped-flow UV/Vis spectroscopic measurements and of CV measurements.</dc:subject>
   <dc:subject>Dataset</dc:subject>
   <dc:source>Agilent Technologies Cary 60 spectrophotometer connected via a Cary 50 fiber optic coupler and combined with a fiber-optic quartz glass immersion probe (Hellma, 1 mm)</dc:source>
   <dc:source>HI-TECH Scientific SF-61SX2 device from TgK Scientific with a charge-coupled device (CCD) photodiode array detector and a xenon arc lamp as light source. The optical path length of the quartz glass cuvette was 10 mm and the mixing time amounts to 2 ms. </dc:source>
   <dc:source>a Metrohm Autolab PGSTAT 101 potentiostat with a three-electrode arrangement with a Pt disc working electrode (1 mm diameter), an Ag wire pseudo reference electrode and a glassy-carbon counter electrode </dc:source>
   <dc:source>Instrument</dc:source>
   <dc:source>Instrument</dc:source>
   <dc:source>Instrument</dc:source>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/legalcode</dc:rights>
   <dc:description>The dataset contains measurement and evaluation data from UV/Vis spectroscopic titration measurements, stopped-flow UV/Vis spectroscopic measurements and CV measurements.</dc:description>
   <dc:subject>copper dioxygen</dc:subject>
   <dc:subject>Bis(µ-oxido) Dicopper Complexes</dc:subject>
   <dc:subject>ultraviolet-visible spectrophotometry</dc:subject>
   <dc:subject>kinetic spectroscopy</dc:subject>
   <dc:subject>electron transfer</dc:subject>
   <dc:subject>Rate Constant</dc:subject>
   <dc:subject>DFT calculation</dc:subject>
   <dc:language>eng</dc:language>
   <dc:format>application/x-tar</dc:format>