<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-13T17:54:06Z</responseDate><request identifier="10.35097/1242" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.35097/1242</identifier><datestamp>2026-10-09T11:05:20Z</datestamp><setSpec>radar4kit</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.35097/1242</dc:identifier>
   <dc:creator>Wadhwa, Sagar</dc:creator>
   <dc:creator>Jouda, Mazin</dc:creator>
   <dc:creator>Deng, Yongbo</dc:creator>
   <dc:creator>Nassar, Omar</dc:creator>
   <dc:creator>Mager, Dario</dc:creator>
   <dc:creator>Korvink, Jan G.</dc:creator>
   <dc:title>Topologically optimized magnetic lens for magnetic resonance applications</dc:title>
   <dc:publisher>Karlsruhe Institute of Technology</dc:publisher>
   <dc:date>2023</dc:date>
   <dc:subject>Engineering</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Dataset</dc:subject>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by-nc/4.0/legalcode</dc:rights>
   <dc:description>Improvements to the signal-to-noise ratio of magnetic resonance detection lead to a strong reduction&#xD;
in measurement time, yet as a sole optimization goal for resonator design, it would be an oversimplification of&#xD;
the problem at hand. Multiple constraints, for example for field homogeneity and sample shape, suggest the use&#xD;
of numerical optimization to obtain resonator designs that deliver the intended improvement. Here we consider&#xD;
the 2D Lenz lens to be a sufficiently broadband flux transforming interposer between the sample and a radiofrequency&#xD;
(RF) circuit and to be a flexible and easily manufacturable device family with which to mediate different&#xD;
design requirements.We report on a method to apply topology optimization to determine the optimal layout of a&#xD;
Lenz lens and demonstrate realizations for both low- (45 MHz) and high-frequency (500 MHz) nuclear magnetic&#xD;