<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-12T20:00:32Z</responseDate><request identifier="10.35097/1508" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.35097/1508</identifier><datestamp>2026-10-09T11:03:19Z</datestamp><setSpec>radar4kit</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.35097/1508</dc:identifier>
   <dc:creator>Ahrens, Mischa</dc:creator>
   <dc:title>Simulation Results for the Evaluation of Strategies for an Adaptive Grid Control System Using Smart Buildings</dc:title>
   <dc:publisher>Karlsruhe Institute of Technology</dc:publisher>
   <dc:date>2023</dc:date>
   <dc:subject>Economics</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Dataset</dc:subject>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/legalcode</dc:rights>
   <dc:description>%%%%% How to interpret the simulation results %%%%%:&#xD;
&#xD;
&#xD;
%%% Main folder naming %%%:&#xD;
&#xD;
"village-future": The simulation scenario (grid and building configuration)&#xD;
&#xD;
"hhOpt": Buildings (households) can optimize their internal energy flows&#xD;
&#xD;
"ONT/RONT": Normal distribution transformer/voltage regulated distribution transformer (VRDT)&#xD;
&#xD;
"QEMS": Quarter energy management system, means that at least one grid control strategy is used&#xD;
&#xD;
"P/Q/PQ/noPQ/noControl": P=active power targets can be used, Q=reactive power control can be used, &#xD;
noPQ=only VRDT can be used, noControl=no grid control at all&#xD;
&#xD;
"full/local-only": Centralized/decentralized grid control strategy&#xD;
&#xD;
"GSUI-60": Grid simulation update interval=60 seconds&#xD;
&#xD;
"d_1970_6_30_0": Start of simulated time is 30 June 1970 00:00 AM&#xD;
&#xD;
&#xD;
%%% Subfolder naming %%%:&#xD;
&#xD;
"s_13749851": Random seed configuration&#xD;
&#xD;
"run_2021-05-25-16-38-29": Starting time of simulation run&#xD;
&#xD;
&#xD;
%%% Subsubfolder naming %%%:&#xD;
&#xD;
"nodeX": Folder for a particular building, numbered according to the grid node, where each building is connected&#xD;
&#xD;
&#xD;
%%% Log files for the entire grid %%%:&#xD;
&#xD;
In general: currentTick is given in Unix time&#xD;
&#xD;
activePowerLog: Active power progressions at all grid nodes in Watt&#xD;
&#xD;
reactivePowerLog: Reactive power progressions at all grid nodes in Var&#xD;
&#xD;
buildingsAggregatedLog: Various power progressions aggregated for all buildings in the grid in Watt&#xD;
&#xD;
currentLog: Current progressions for all lines in the grid in Ampere&#xD;
&#xD;
gridSimulationAggregated: Various grid characteristics aggregated over the entire simulation run, &#xD;
voltages and line utilizations are normalized to nominal values&#xD;
&#xD;
mediumVoltageAggregated: Aggregated characteristics of the voltage at the primary side of the transformer in pu&#xD;
&#xD;
mediumVoltageLog: Progression of the voltage at the primary side of the transformer in pu&#xD;
&#xD;
transformerAggregatedLog: Aggregated characteristics of the transformer, temperatures are given in °C, remaining values have to unit&#xD;
&#xD;
transformerStepLog:Progression of VRDT steps, remains 0 if no VRDT is used, no unit&#xD;
&#xD;
transformerTemperatureLog: Progression of various transformer characteristics, temperatures are given in °C, &#xD;
remaining values have to unit&#xD;
&#xD;
voltageLog: Progressions of voltages at all nodes in the grid in pu&#xD;
&#xD;
&#xD;
%%% Log files for specific buildings %%%:&#xD;
&#xD;
DISHWASHER/DRYER/ELECTRICSTOVE/INDUCTIONCOOKTOP/WASHINGMACHINE:&#xD;
TOTAL=number of planned appliance runs, AVGTOTAL=number of expected appliance runs based on probality distributions, &#xD;
REALTOTAL=number of realized appliance runs, TOTAL0/TOTAL1=number of realized appliance runs for different running profiles&#xD;
&#xD;
batteryLog: &#xD;
Progressions of battery energy storage system active charge/discharge power in Watt, &#xD;
reactive charge/discharge power in Var and state of charge in Watt*second, &#xD;
positive values denote charging, negative values discharging&#xD;
&#xD;
electricVehicleLog: Progressions of electric vehicle active charge power in Watt, reactive charge power in Var&#xD;
&#xD;
powerLog: Progressions of various building powers in Watt, prices and costs in Euro-cent&#xD;
&#xD;
simResultsAggregated: Various aggregated energy amounts in kWh and costs in Euro-cent</dc:description>
   <dc:identifier>10.5445/IR/1000133331</dc:identifier>
   <dc:identifier>KITopen-DOI</dc:identifier>
   <dc:format>application/x-tar</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>