<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-12T11:19:14Z</responseDate><request identifier="10.35097/1930" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.35097/1930</identifier><datestamp>2026-10-09T11:02:35Z</datestamp><setSpec>radar4kit</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.35097/1930</dc:identifier>
   <dc:creator>Das, Srashtasrita</dc:creator>
   <dc:creator>Stuckelberger, Michael E.</dc:creator>
   <dc:creator>Pottbacker, Jan</dc:creator>
   <dc:creator>Jakobtorweihen, Sven</dc:creator>
   <dc:creator>Schroer, Christian G.</dc:creator>
   <dc:creator>Horn, Raimund</dc:creator>
   <dc:creator>Sheppard, Thomas Lennon</dc:creator>
   <dc:title>Resonant STXM-CT on single wire extracted from Pt/Rh gauzes treated under ammonia oxidation conditions for 50 h</dc:title>
   <dc:publisher>Karlsruhe Institute of Technology</dc:publisher>
   <dc:date>2024</dc:date>
   <dc:subject>Engineering</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Dataset</dc:subject>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by/4.0/legalcode</dc:rights>
   <dc:description>This tomographic scanning transmission X-ray microscopy (STXM-CT) data was acquired at the P06 microprobe beamline of the PETRA III (Deutsches-Elektronen Synchrotron DESY, Hamburg). The sample measured during this experiment was a single wire extracted from the Pt/Rh gauzes aged under industrial ammonia oxidation conditions for 50 h of time on stream. A detailed description of the dataset can be found in the corresponding readme file and its associated publication.</dc:description>
   <dc:description>This tomographic scanning transmission X-ray microscopy (STXM-CT) data was acquired at the P06 microprobe beamline of the PETRA III (Deutsches-Elektronen Synchrotron DESY, Hamburg). The sample measured during this experiment was a single wire extracted from the Pt/Rh gauzes aged under industrial ammonia oxidation conditions for 50 h of time on stream. A detailed description of the dataset can be found in the corresponding readme file and its associated publication.</dc:description>
   <dc:description>In this experiment, ex situ STXM-CT was performed on single wires, with angles ranging from 0 to 360 degrees. The single wires were extracted from aged Pt/Rh gauzes treated under industrial ammonia oxidation conditions for 50 h of reaction time. The data available here contains the final and processed tomographic volumes of the wire measured at two energies above and below the Rh K-edge, at 23300 eV and 23208 eV respectively. Each 3D volume has been stacked as slices in each TIFF file provided here.</dc:description>
   <dc:format>application/x-tar</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>