<?xml version="1.0" encoding="UTF-8" ?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-12T15:45:11Z</responseDate><request identifier="10.35097/4c872ct4ezbhs4rt" metadataPrefix="oai_dc" verb="GetRecord">https://www.radar-service.eu/oai/OAIHandler</request><GetRecord><record><header><identifier>10.35097/4c872ct4ezbhs4rt</identifier><datestamp>2026-10-09T11:01:30Z</datestamp><setSpec>radar4kit</setSpec></header><metadata><oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/"
           xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"
           xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
           xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ https://www.openarchives.org/OAI/2.0/oai_dc.xsd">
   <dc:identifier>https://dx.doi.org/10.35097/4c872ct4ezbhs4rt</dc:identifier>
   <dc:creator>Zeb, Alam</dc:creator>
   <dc:creator>Bilal, Salma</dc:creator>
   <dc:creator>Begum, Bushra</dc:creator>
   <dc:creator>Ul Haq Ali Shah, Anwar</dc:creator>
   <dc:creator>Röse, Philipp</dc:creator>
   <dc:title>Redox-Active Polyindole-Modified Electrode for Electrochemical Quantification of Uric Acid</dc:title>
   <dc:publisher>Karlsruhe Institute of Technology</dc:publisher>
   <dc:date>2026</dc:date>
   <dc:subject>Engineering</dc:subject>
   <dc:type>dataset</dc:type>
   <dc:subject>Dataset</dc:subject>
   <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
   <dc:rights>https://creativecommons.org/licenses/by-sa/4.0/legalcode</dc:rights>
   <dc:description>Uric acid (UA) is an important clinical biomarker whose reliable determination in complex biological media is often hampered by co-existing electroactive interferents. Intrinsically conducting polymers are versatile materials for electrochemical sensing, yet polyindole (PIn) has remained largely unexplored for this purpose. Here, we report a PIn-modified glassy carbon electrode for the non-enzymatic determination of UA in neutral phosphate buffer. PIn was synthesized by chemical oxidative polymerization in the presence of sulfonate dopants and deposited as a thin film on glassy carbon; physicochemical characterization confirmed a doped, conjugated, and nanostructured coating with a high effective surface area. The electrode showed a well-defined UA oxidation signal and, by chronoamperometry, a linear response over 0.01-0.10 mM with a sensitivity of 4.53 µA cm-2 mM-1 and a limit of detection of 4.0 M. Under the applied conditions, ascorbic acid, dopamine, glucose, and sodium chloride contributed only marginally to the response, and the sensor performed reliably in diluted human serum, with recoveries of 99.7-99.9% and relative standard deviations below 5%. These findings identify polyindole as a promising, still underexplored intrinsically conducting polymer for electrochemical biosensing.</dc:description>
   <dc:description>Uric acid (UA) is an important clinical biomarker whose reliable determination in complex biological media is often hampered by co-existing electroactive interferents. Intrinsically conducting polymers are versatile materials for electrochemical sensing, yet polyindole (PIn) has remained largely unexplored for this purpose. Here, we report a PIn-modified glassy carbon electrode for the non-enzymatic determination of UA in neutral phosphate buffer. PIn was synthesized by chemical oxidative polymerization in the presence of sulfonate dopants and deposited as a thin film on glassy carbon; physicochemical characterization confirmed a doped, conjugated, and nanostructured coating with a high effective surface area. The electrode showed a well-defined UA oxidation signal and, by chronoamperometry, a linear response over 0.01-0.10 mM with a sensitivity of 4.53 µA cm-2 mM-1 and a limit of detection of 4.0 M. Under the applied conditions, ascorbic acid, dopamine, glucose, and sodium chloride contributed only marginally to the response, and the sensor performed reliably in diluted human serum, with recoveries of 99.7-99.9% and relative standard deviations below 5%. These findings identify polyindole as a promising, still underexplored intrinsically conducting polymer for electrochemical biosensing.</dc:description>
   <dc:description>Data for Figures in the Manuscript&#xD;
&#xD;
Figure 1:&#xD;
&#xD;
File names: &#xD;
Figure_1a_FTIR_PIn&#xD;
Figure_1b_xrd_PIn&#xD;
&#xD;
Description:&#xD;
FTIR spectrum (a) and X-ray diffraction pattern (b) of chemically synthesized, doped polyindole (PIn).&#xD;
&#xD;
Conditions:&#xD;
Sample: chemically synthesized polyindole doped with H₂SO₄ and DBSA, FTIR: ATR mode; spectral range 400–3500 cm⁻¹; resolution 2 cm⁻¹; temperature: room temperature; XRD: Bruker D8 ADVANCE with Cu Kα radiation (λ = 1.54 Å); tube settings 40 kV and 40 mA; 2θ range 10–70°; step size 0.01°; scan speed 2 steps s⁻¹; temperature: room temperature.&#xD;
&#xD;
Figure 2:&#xD;
&#xD;
File name: Figure_2_SEM_PIn&#xD;
&#xD;
Description:&#xD;
SEM images of polyindole at different magnifications showing granular, approximately spherical particles and rough surface morphology.&#xD;
&#xD;
Conditions:&#xD;
Sample: polyindole powder deposited on a conductive carbon substrate; instrument: SEM (Supra 55VP, ZEISS FEGSEM) with field-emission gun; imaging in high-vacuum mode; temperature: 20 °C&#xD;
&#xD;
Figure 3:&#xD;
&#xD;
File names&#xD;
Figure_3a_CV_glassy_carbon&#xD;
Figure_3b_CV_PIn&#xD;
&#xD;
Description:&#xD;
Cyclic voltammograms of (a) bare glassy carbon (GC) electrode and (b) PIn-modified GC electrode in 1 M H₂SO₄ at different scan rates, showing featureless response for bare GC and a well-defined redox couple for PIn/GC.&#xD;
&#xD;
Conditions:&#xD;
Electrochemical cell: three-electrode configuration; working electrode: bare GC (a) or PIn-modified GC (b); reference electrode: Ag/AgCl (KCl-saturated, aqueous); counter electrode: gold sheet; electrolyte: 1.0 M H₂SO₄ (aqueous); temperature: 25 °C; technique: cyclic voltammetry; scan rates: 10–150 mV s⁻¹; potential window -0.2 V to 0.8 V vs. Ag/AgCl&#xD;
&#xD;
Figure 4:&#xD;
&#xD;
File names:&#xD;
Figure_4a_CV_PIn_buffer&#xD;
Figure_4b_linearity_sqrt(nu)_vs_jp&#xD;
Figure_4c_CV_UA_concentration_variation&#xD;
Figure_4d_concentration_vs_peak_current_densities&#xD;
&#xD;
Description:&#xD;
(a) CVs of the PIn-modified GC electrode in 0.1 M PBS (pH 7.0) at various scan rates without uric acid; (b) plot of peak current density vs. square root of scan rate; (c) CVs at 50 mV s⁻¹ in PBS for different uric acid concentrations; (d) calibration plot of anodic peak current density vs. uric acid concentration.&#xD;
&#xD;
Conditions:&#xD;
Electrochemical cell: three-electrode configuration; working electrode: PIn-modified GC; reference electrode: Ag/AgCl (KCl-saturated); counter electrode: gold coil; electrolyte: 0.1 M phosphate buffer solution (PBS), pH 7.0; temperature: 25 °C; (a,b) uric acid-free PBS; scan rates: 10–110 mV s⁻¹; potential window: -0.2 to +0.8 V vs. Ag/AgCl; (c,d) uric acid in PBS at concentrations spanning 0.2–3.5 mM; scan rate: 50 mV s⁻¹; currents normalized to electrochemically active surface area (ECSA).&#xD;
&#xD;
Figure 5:&#xD;
&#xD;
File names:&#xD;
Figure_5a_CA_UA_concenctration&#xD;
Figure_5b_UA_concentration&#xD;
Figure_5c_cross_sensitivity&#xD;
Figure_5d_long_term_stability&#xD;
&#xD;
Description:&#xD;
(a) Chronoamperometric current–time curves for successive additions of uric acid at a fixed potential; (b) calibration plot of steady-state current density vs. uric acid concentration; (c) chronoamperometric responses to uric acid and common interferents; (d) long-term stability of the uric acid response over 9 days.&#xD;
&#xD;
Conditions:&#xD;
Electrochemical cell: three-electrode configuration; working electrode: PIn-modified GC; reference electrode: Ag/AgCl (KCl-saturated); counter electrode: gold coil; electrolyte: 0.1 M PBS, pH 7.0; temperature: 25 °C; technique: chronoamperometry; applied potential: 0.5 V vs. Ag/AgCl; (a,b) uric acid additions in PBS, concentration range 0.2–3.5 mM; currents evaluated at quasi-steady state; (c) analytes: 0.3 mM uric acid, 5 mM glucose, 1 mM NaCl, 0.1 mM ascorbic acid, 0.001 mM dopamine, each in 0.1 M PBS at 0.5 V; (d) repeated uric acid measurements once per day over 9 days at fixed uric acid concentration (within linear range) and 0.5 V vs. Ag/AgCl; currents expressed as (mu)A cm_ECSA⁻² and normalized to initial response.&#xD;
&#xD;
Figure 6:&#xD;
&#xD;
File name:&#xD;
Figure_6a_DPV&#xD;
Figure_6b_linearity_c_vs_jp&#xD;
Figure_6c_mixed_interferences&#xD;
&#xD;
Description:&#xD;
(a) DPV of PIn with difference UA concentrations&#xD;
(b) Plot of UA concentrations vs peak current densities jp&#xD;
(c) bar plot of UA with different concentrations and mixtures of interferences&#xD;
&#xD;
Conditions:&#xD;
Electrochemical cell: three-electrode configuration; working electrode: PIn-modified GC; reference electrode: Ag/AgCl (KCl-saturated); counter electrode: gold coil; electrolyte: 0.1 M PBS, pH 7.0; temperature: 25 °C; technique: differential pulse voltammetry (DPV); applied potential: 0.1 V to 0.65 V vs. Ag/AgCl, step size 2 mV, amplitude 5 mV; (a,b) uric acid additions in PBS, concentration range 0.03–0.25 mM; (c) analytes: 1 mM uric acid, 1 mM glucose, 1 mM NaCl, 0.1 mM ascorbic acid, 0.001 mM dopamine, each in 0.1 M PBS at 0.5 V; currents expressed as (mu)A cm_ECSA⁻² and normalized to initial response.</dc:description>
   <dc:subject>electrochemical sensor</dc:subject>
   <dc:subject>intrinsically conducting polymer</dc:subject>
   <dc:subject>Polyindole</dc:subject>
   <dc:subject>uric acid</dc:subject>
   <dc:subject>non-enzymatic sensor</dc:subject>
   <dc:subject>selectivity</dc:subject>
   <dc:relation>https://publikationen.bibliothek.kit.edu/1000188618</dc:relation>
   <dc:format>application/x-tar</dc:format>
</oai_dc:dc></metadata></record></GetRecord></OAI-PMH>