Alternativer Identifier:
(KITopen-DOI) 10.5445/IR/1000132478
Verwandter Identifier:
-
Ersteller/in:
Weber, Sebastian https://orcid.org/0000-0003-2518-9340 [Weber, Sebastian]

Sheppard, Thomas L. [Sheppard, Thomas L.]
Beitragende:
(Other)
Batey, Darren [Batey, Darren]

(Other)
Cipiccia, Silvia [Cipiccia, Silvia]

(Other)
Stehle, Matthias [Stehle, Matthias]

(Other)
Abel, Ken L. [Abel, Ken L.]

(Other)
Gläser, Roger [Gläser, Roger]
Titel:
Reconstructed ptychographic X-ray computed tomography data of an activated mesoporous Ni/Al$_{2}$O$_{3}$ catalyst
Weitere Titel:
-
Beschreibung:
(Abstract) Reconstructed ptychographic X-ray computed tomography data set acquired at Diamond Light Source, instrument I13-1 (proposal MG24079-1) of the activated mesoporous sample Ni/Al$_{2}$O$_{3}$-ma. The data set is part of an artificial coking study of nickel based catalysts, which were investigated by ptychographic X-ray computed tomography. Detailed information regarding sample preparation and experimental conditions are available in the respective publication and electronic supplementary information.
(Abstract) Reconstructed ptychographic X-ray computed tomography data set acquired at Diamond Light Source, instrument I13-1 (proposal MG24079-1) of the activated mesoporous sample Ni/Al$_{2}$O$_{3}$-ma. The data set is part of an artificial coking study of nickel based catalysts, which were investigated by ptychographic X-ray computed tomography. Detailed information regarding sample preparation and experimental conditions are available in the respective publication and electronic supplementary information.
(Technical Remarks) The data contains the reconstructed tomogram slices in a "*.tiff" format as delta contrast tomogram. The correction of the delta tomogram and calculation of the electron density tomogram has to be done as described in the "*_cutoffs.txt" file. Information about required offset correction of the electron density tomograms is provided in the respective publication. Reconstructed X-ray ptychography projections were tomographically reconstructed using the Matlab script of the cSAXS group of the Swiss Light Source, as published in DOI:10.5281/zenodo.3539550 and DOI:10.1364/OE.27.036637. Ptychographic projections were obtained using the PtyRex package available at I13-1 beamline with 400 iterations.
Schlagworte:
Tomography
Catalysis
X-rays
Zugehörige Informationen:
-
Sprache:
-
Erstellungsjahr:
Fachgebiet:
Engineering
Objekttyp:
Dataset
Datenquelle:
-
Verwendete Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:

Sheppard, Thomas L.
Förderung:
-
Name Speichervolumen Metadaten Upload Aktion

Zugriffe der letzten sechs Monate

Aufrufe der Datenpaket-Seite

211


Downloads des Datenpakets

0


Gesamtstatistik

Zeitraum Aufrufe der Datenpaket-Seite Datenpaket heruntergeladen
Mai 2024 11 0
Apr. 2024 62 0
März 2024 37 0
Feb. 2024 32 0
Jan. 2024 37 0
Dez. 2023 32 0
Vorher 164 0
Gesamt 375 0
Status:
Publiziert
Eingestellt von:
kitopen
Erstellt am:
Archivierungsdatum:
2023-06-24
Archivgröße:
439,5 MB
Archiversteller:
kitopen
Archiv-Prüfsumme:
ca0d338289d0381a0bfc31b0a972ed83 (MD5)
Ende des Embargo-Zeitraums:
-