Alternativer Identifier:
-
Verwandter Identifier:
-
Ersteller/in:
Langletz, Tim https://orcid.org/0000-0002-4174-8547 [Institute of Inorganic Chemistry, RWTH Aachen University, Landoltweg 1a, 52074 Aachen, Germany and Bioeconomy Science Center (BioSC), Forschungszentrum Jülich GmbH, 52425 Jülich]

Edinger, Medea https://orcid.org/0009-0007-7964-6582 [Institute of Inorganic Chemistry, RWTH Aachen University, Landoltweg 1a, 52074 Aachen]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [Institute of Inorganic Chemistry, RWTH Aachen University, Landoltweg 1a, 52074 Aachen]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [Institute of Inorganic Chemistry, RWTH Aachen University, Landoltweg 1a, 52074 Aachen, Germany and Bioeconomy Science Center (BioSC), Forschungszentrum Jülich GmbH, 52425 Jülich]
Beitragende:
-
Titel:
Experimental data to the publication "From Biomass to Polymers: Kinetic Analysis and Sustainable Synthesis of Lignin-Polycaprolactone Copolymers "
Weitere Titel:
-
Beschreibung:
(Abstract) NMR spectroscopic data and SEC data for the synthesis of Lignin-Polycaprolactone Copolymers were deposited.
Schlagworte:
NMR spectroscopy
SEC data
lignin polymerization
Zugehörige Informationen:
-
Sprache:
Englisch
Herausgeber/in:
Erstellungsjahr:
Fachgebiet:
Chemistry
Materials Science
Objekttyp:
(Dataset) NMR spectroscopic data and SEC experimental data
Datenquelle:
(Instrument) Bruker Avance II (400 MHz)
(Instrument) Bruker Avance III (400 MHz)
(Instrument) Viscotek GPCmax VE-2001 with a flow rate of 1 ml min-1 at 25 °C with THF as mobile phase. The system was equipped with two Malvern Viscotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 Å and 5000 Å, a HPLC pump, a refractive index detector (VE-3580), and a viscometer (Viscotek 270 Dual detector). The results were evaluated using a conventional calibration using polystyrene standards. The respective molecular weights are given in polystyrene equivalents.
Verwendete Software:
Software für Datenerhebung
Software:
Topspin - Version 3.5 pl 7 for Bruker Avance III HD 400
TopSpin - Version 2.1 for Bruker Avance II 400
Omnisec - 5.12
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
MestReNova - Version 14.2.3 – 29241
Alternative Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
Förderung:
Bioeconomy Science Center - (LignoTex)(The scientific activities of the Bioeconomy Science Center were financially supported by the Ministry of Innovation, Science and Research within the framework of the NRW Strategieprojekt BioSC (no. 313/323-400-002 13).)
Name Speichervolumen Metadaten Upload Aktion
Status:
Publiziert
Eingestellt von:
iac_Radar_Produktion
Erstellt am:
Archivierungsdatum:
2025-06-04
Archivgröße:
7,4 MB
Archiversteller:
iac_Radar_Produktion
Archiv-Prüfsumme:
5dd796169734593b358a58bbc2d74cd9 (MD5)
Embargo-Zeitraum:
-