Alternativer Identifier:
-
Verwandter Identifier:
(Is Supplement To) 10.1371/journal.pone.0299050 - DOI
Ersteller/in:
Kettner, Cagla https://orcid.org/0000-0003-4283-281X [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]

Stein, Thorsten https://orcid.org/0000-0002-7885-7085 [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]
Beitragende:
(Researcher)
Kanus, Lisa [Department of Prosthodontics, University of Würzburg]

(Researcher)
Möhler, Felix https://orcid.org/0000-0002-2082-4811 [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]

(Researcher)
Ringhof, Steffen [Department of Diagnostic and Interventional Radiology, University of Freiburg]

(Researcher)
Hellmann, Daniel [Department of Prosthodontics, University of Würzburg]

(Researcher)
Schmitter, Marc [Department of Prosthodontics, University of Würzburg]
Titel:
Data for "Persisting effects of jaw clenching on dynamic steady-state balance"
Weitere Titel:
-
Beschreibung:
(Abstract) The research project "Influence of the craniomandibular system on human postural control" is funded by the German Research Foundation (DFG). The aim of the project is to investigate for the first time the influences of controlled motor activity of the craniomandibular system (CMS) on human postural ...

(Technical Info) In this experiment, 48 physically active adults aged between 18 and 30 years are tested. The experimental design includes two measurement times with a two-week intervention phase inbetween. A stability platform (Lafayette Instrument Company, Indianapolis, US) is used to evaluate the postural dynamic...

(Table Of Contents) o Raw data o Fully labeled data o Demographic (gender) and anthropometric (e.g., height, weight) data o Methods are described in the referred paper
Schlagworte:
stomatognathic activity
postural control
temporomandibular joint
Stabiliometer
steady-state balance
Zugehörige Informationen:
-
Sprache:
Englisch
Erstellungsjahr:
Fachgebiet:
Sports
Life Science
Objekttyp:
Dataset
Datenquelle:
(Instrument) Infrared camera-based motion capturing: Vicon Motion Systems; Oxford Metrics Group, Oxford, UK; 10 Vantage V8 and 6 Vero V2.2 cameras; 200 Hz
(Instrument) Wireless EMG system: Noraxon U.S.A., Inc.; Scottsdale, AZ, USA; 2,000 Hz; Bipolar Ag/AgCl surface electrodes with a diameter 14 mm
Verwendete Software:
Software für Datenerhebung
Software:
Vicon Nexus - 2.10
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
MATLAB - R2020a
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
SPSS - 25.0
Alternative Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
Förderung:
Name Speichervolumen Metadaten Upload Aktion
Status:
Publiziert
Eingestellt von:
c97b74e0a3438db2d4b0806e428161e2
Erstellt am:
Archivierungsdatum:
2026-02-20
Archivgröße:
66,4 GB
Archiversteller:
bdbf2619140df79398807b21caa53e90
Archiv-Prüfsumme:
18dde05632d6e00d06c9127a6baf5127 (MD5)
Embargo-Zeitraum:
-