Alternativer Identifier:
-
Verwandter Identifier:
(Is Supplement To) 10.1039/D3CY01117H - DOI
Ersteller/in:
Conrads, Christian https://orcid.org/0000-0001-9606-8306 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Burkart, Lisa [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Soerensen, Sven [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Noichl, Sandra [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Kara, Yasemin [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Heck, Joshua https://orcid.org/0000-0001-8895-1289 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen, Germany]
Beitragende:
-
Titel:
Experimental Data to the publication "Understanding Structure-Activity Relationships: Iron(II) Complexes of “Legacy Guanidines” as Catalysts for the Synthesis of Polylactide"
Weitere Titel:
-
Beschreibung:
(Abstract) NMR spectroscopic data, GPC data, DSC data and Raman spectroscopic data for the ring-opening polymerisation of lactide and depolymerisation of polylactide of a series of non toxic Fe catalyst were deposited.
Schlagworte:
NMR spectroscopy
lactide polymerisation
depolymerisation of polylactide
Raman spectroscopy
MALDI-TOF-MS spectra
Zugehörige Informationen:
-
Sprache:
Englisch
Herausgeber/in:
Erstellungsjahr:
Fachgebiet:
Chemistry
Materials Science
Objekttyp:
(Dataset) NMR, GPC, DSC and Raman spectroscopic experimental data and MALDI-TOF-MS spectra
Datenquelle:
(Instrument) Bruker Avance II (400MHz)
(Instrument) Bruker Avance III (400MHz)
(Instrument) Bruker Avance Neo (400MHz)
(Instrument) GPCmax VE-2001 from Viscotek: two Malvern Viscotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 and 5000Å, a refractive index detector (VE-3580), and a viscometer (Viscotek 270 Dual Detector)
(Instrument) Netzsch DSC 204 F1 Phoenix equipped with an intra-cooler
(Instrument) RXN1 spectrometer of Kaiser Optical System with a 785nm laser
(Instrument) Bruker ultrafleXtreme equipped with a 337 nm smart beam laser in the reflective mode was used. The protein mixture Protein 1 calibration standard was used for calibration. For the spectra, 4000 laser shots with 24% laser power were collected. The laser repetition rate was 1000 Hz.
Verwendete Software:
Software für Datenerhebung
Software:
TopSpin - 2.1
TopSpin - 3.5 pl 7
TopSpin - 4.2.0
Omnisec - 5.12
Proteus - 8.0.3
iC Raman - V 4.1
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
MestReNova - 12.0.1
Alternative Software:
PEAXACT - 4.6
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
Förderung:
European Commission - (sUstainable PLastIcs for the Food and drink packaging indusTry (UPLIFT)) H2020: 953073
Name Speichervolumen Metadaten Upload Aktion

Zugriffe der letzten sechs Monate

Aufrufe der Datenpaket-Seite

294


Downloads des Datenpakets

2


Gesamtstatistik

Zeitraum Aufrufe der Datenpaket-Seite Datenpaket heruntergeladen
Juli 2024 34 0
Juni 2024 49 1
Mai 2024 56 1
Apr. 2024 46 0
März 2024 41 0
Feb. 2024 68 0
Vorher 225 1
Gesamt 519 3
Status:
Publiziert
Eingestellt von:
iac_Radar_Produktion
Erstellt am:
Archivierungsdatum:
2023-09-19
Archivgröße:
168,1 MB
Archiversteller:
iac_Radar_Produktion
Archiv-Prüfsumme:
644ee0e01ba5c2727dad8dcf06831430 (MD5)
Ende des Embargo-Zeitraums:
-