The data set contains the raw as well as the evaluated data from a subject study with 6 subjects to measure the mechanical impedance and the vibration power absorbtion while varying the grip and push forces in four levels between 25-135N and 30-100N respectively. For each subject 10 additional measurements at random grip and push force combinations were recorded for validation purposes. The subjects were randomised to hold the force levels while the measurement handle was excitated around the lower arm axis (zh-axis according to DIN5349:2001) to their hand-arm system via a shaker system, with the posture of the subjects lying within the ranges specified in ISO 10819:2022. The measuring handle on which the study was conducted complies with the specifications in ISO10068:2012 for translatory excitations. To calibrate the handle for rotational excitation, a calibration function was calculated by exciting the handle with different weights. The excitation was a multisine with frequencies between 10 to 500 Hz in 5 Hz increments. Between 10 to 30Hz the amplitude of the multisines angular acceleration in the frequency domain are linearly increased from 20 to 100rad/s². From 30 to 500Hz to amplitude of the angular acceleration is at each frequency of the multisine 100rad/s². The acquisition time of each measurement is 16.5 sec, for the evaluation the data is cutted to exclude the first 2 sec and the last 3.5 sec.
The data set for translatory excitation in zh-direction is published as: DOI: 10.35097/uwz0qdyzh8h8uekw KITopen-ID: 1000181216