Alternativer Identifier:
-
Verwandter Identifier:
(Is Supplement To) 10.1002/adsu.202200359 - DOI
Ersteller/in:
Conen, Niclas [RWTH Aachen University, Fluid Process Engineering (AVT.FVT), Forckenbeckstraße 51, 52074 Aachen (Germany)]

Fuchs, Martin [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen (Germany)]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen (Germany)]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 52074 Aachen (Germany)]

Jupke, Andreas https://orcid.org/0000-0001-6551-5695 [RWTH Aachen University, Fluid Process Engineering (AVT.FVT), Forckenbeckstraße 51, 52074 Aachen (Germany)]
Beitragende:
-
Titel:
Experimental data to the publication "Taking the next step – Model-based analysis of robust and non-toxic Zn catalysts for the ring opening polymerization of lactide in the polymer melt"
Weitere Titel:
-
Beschreibung:
(Abstract) The coordination geometries of the hypersurface, all NMR spectroscopic data, all GPC data and Raman spectroscopic data were deposited for a model-based analysis of robust and non-toxic Zn catalysts for the ring opening polymerization of lactide in the polymer melt.
Schlagworte:
NMR spectroscopy
raman spectroscopy
gel permeation chromatography
lactide polymerisation
Zugehörige Informationen:
-
Sprache:
Englisch
Herausgeber/in:
RWTH Aachen University
Erstellungsjahr:
Fachgebiet:
Chemistry
Engineering
Objekttyp:
(Dataset) NMR, GPC and Raman experimental data
Datenquelle:
(Instrument) Bruker Avance II (400MHz)
(Instrument) Bruker Avance III (400MHz)
(Instrument) GPCmax VE-2001 from Viscotek: two Malvern Viscotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 and 5000Å, a refractive index detector (VE-3580), and a viscometer (Viscotek 270 Dual Detector)
(Instrument) RXN1 spectrometer of Kaiser Optical System with a 785nm laser
Verwendete Software:
Software für Datenerhebung
Software:
TOPSPIN - 2.1
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
iC Raman - V 4.1
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
PEAXACT - 4.6
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
Omnisec - 5.12
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
MestReNova - 12.0.1-20560
Alternative Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
RWTH Aachen University
Förderung:
Deutsche Forschungsgemeinschaft - (under German Excellence Initiative)(G:(DE-82)EXS-PF-PFKA007)
Name Speichervolumen Metadaten Upload Aktion
Status:
Publiziert
Eingestellt von:
iac_Radar_Produktion
Erstellt am:
Archivierungsdatum:
2022-05-16
Archivgröße:
114,2 MB
Archiversteller:
iac_Radar_Produktion
Archiv-Prüfsumme:
4f58e017233e50be6aa8d403caabe563 (MD5)
Embargo-Zeitraum:
-

Standort

  • Aachen, GERMANY