Alternativer Identifier:
-
Verwandter Identifier:
-
Ersteller/in:
Becker, Tabea https://orcid.org/0009-0007-5243-1952 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 5207 Aachen, Germany and Bioeconomy Science Center (BioSC), Forschungszentrum Jülich GmbH, 52425 Jülich, Germany]

Hermann, Alina [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 5207 Aachen, Germany and Bioeconomy Science Center (BioSC), Forschungszentrum Jülich GmbH, 52425 Jülich, Germany]

Saritas, Nazik [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 5207 Aachen, Germany]

Hoffmann, Alexander https://orcid.org/0000-0002-9647-8839 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 5207 Aachen, Germany]

Herres-Pawlis, Sonja https://orcid.org/0000-0002-4354-4353 [RWTH Aachen University, Institute of Inorganic Chemistry, Landoltweg 1a, 5207 Aachen, Germany and Bioeconomy Science Center (BioSC), Forschungszentrum Jülich GmbH, 52425 Jülich, Germany]
Beitragende:
-
Titel:
Experimental Data to the publication "Open- and Closed-Loop Recycling: Highly Active Zinc Bisguanidine Polymerization Catalyst for the Depolymerization of Polyesters"
Weitere Titel:
-
Beschreibung:
(Abstract) NMR spectroscopic data, GPC data, kinetic data and data for the determination of the activation energy, activation enthalpy and the activation entropy via an Eyring plot for the depolymerisation activity of polylactide, catalyst recycling, scale-up experiments and solvent-free alcoholysis of a non toxic Zn catalyst were deposited.
Schlagworte:
NMR spectroscopy
depolymerisation
Polylactide
guanidine complex
Zugehörige Informationen:
-
Sprache:
Englisch
Herausgeber/in:
Erstellungsjahr:
Fachgebiet:
Materials Science
Chemistry
Objekttyp:
(Dataset) NMR, GPC and kinetic experimental data
Datenquelle:
(Instrument) Bruker Avance II (400 MHz)
(Instrument) Bruker Avance III (400 MHz)
(Instrument) GPCmax VE-2001 from Viscotek: two Malvern Vicotek T columns (porous styrene divinylbenzene copolymer) with a maximum pore size of 500 and 5000 Å, a refractive index detectort (VE-3580), and a viscosimeter (Vircotek 270 Dual Detector)
Verwendete Software:
Software für Datenerhebung
Software:
TOPSPIN - 2-1
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
TOPSPIN - 3.5 pl 7
Alternative Software:
-
Verwendete Software:
Software für Datenerhebung
Software:
Omnisec - 5.12
Alternative Software:
-
Verwendete Software:
Software für Datenbearbeitung
Software:
MestReNova - 14.2.3-29241
Alternative Software:
-
Datenverarbeitung:
-
Erscheinungsjahr:
Rechteinhaber/in:
Förderung:
-
Name Speichervolumen Metadaten Upload Aktion
Status:
Publiziert
Eingestellt von:
iac_Radar_Produktion
Erstellt am:
Archivierungsdatum:
2024-06-12
Archivgröße:
64,3 MB
Archiversteller:
iac_Radar_Produktion
Archiv-Prüfsumme:
395aa258056bae7862e3faefe5f7b04b (MD5)
Embargo-Zeitraum:
-